Your One Stop Stocking Distributor - Mitchell Instrument Company - call toll free: (888) 270 2690

Skip to Main Content »

Search Site
Welcome! Have Questions? Call us at: (888) 270 2690

You're currently on:

Mitchell Instrument Company Free Shipping Offer
Mitchell Instrument Company SSL Security Information
Mitchell Instrument Company Contact Us
Mitchell Instrument Company Calibration Services
Secure Credit Card Checkout available for Visa Mastercard and American Express

 

Newsletter

Newsletter
 

Megger CFL535F TDR

Double click on above image to view full picture

Zoom Out
Zoom In

More Views

Megger CFL535F Cable Fault Locator

Mitchell Part Number: AVO-655535E

See other products by Megger

Availability: Typically In stock.

Regular Price: $3,279.00

Special Price: $2,949.00

Add Items to Cart Add to Cart

Quick Overview

The Megger CFL535F TDR2000/2 is a state of the art monochrome dual channel Time Domain Reflectometer, capable of identifying and locating a wide range of faults on metallic cables.

Be the first to review this product

The TDR2000/2 has a minimum resolution of 0.1m and a maximum range of 20 km at VF=0.9 and 16 Km (48,000 ft.) at 0.65 VF. The TDR2000/2 can perform single or dual channel measurements on a wide range of metallic cables. Active channels can be compared with each other or with previously stored traces from memory. Differential channel measurements are possible and cross talk between channels can also be identified.


Intermittent Mode
An ‘intermittent mode’ continually updates and shows any transient reflections. Any intermittent fault leaves a
permanent record on the display, capturing elusive faults.


Dual cursors
The TDR2000/2 can display either single or dual cursors. Single cursor mode displays the distance from the start of the cable to the cursor. In dual cursor mode the distance between faults can be measured.


Fast Find Key
One press of the find key automatically adjusts the range and gain and positions the cursor to the major event on the cable.


Tx Null
Tx Null helps eliminate the ‘dead zone’ at the start of the displayed trace, normally obscured by the transmission pulse. By the adjusting the Tx Null the user can see these ‘near end’ faults more clearly.


Output Pulse Control
Both the amplitude and width of the output pulse can be adjusted to provide the best possible reflection for accurate location of cable faults.


Interactive Help Screen
A full graphical help screen is available with keyboard layout and individual key operation. At the press of a button.


Trace Storage
15 internal trace memories provide for the storage and recall of test results. The traces can be recalled to the display for analysis or compared with an active display to aid in fault location. Alternatively the stored results can be downloaded to a computer, over the RS232 port, using the TraceMaster software and RS232 lead provided.

Product Includes Test and carry pouch, serial data lead, miniature clip test lead set, carry strap, and TraceMaster software.
Specifications

Ranges
50 m, 100 m, 200 m, 400 m, 1 km, 2 km, 4 km, 8 km, 16 km
(150 ft, 300 ft, 600 ft, 1200 ft, 3000 ft, 6000 ft, 12000 ft, 24000 ft,48000 ft)
Resolution
0.1 m (4in.) up to 200 m (600 ft)
0.2 m (8 in.) up to 400 m (1200 ft)
0.1% of range above 400 m (1200 ft)
Measurement Accuracy
0.1% of Range
[Note – The measurement accuracy is for the indicated cursor
position only and is conditional on the velocity being correct]
Input Impedance: 120 ½.
Input Protection: 300 V CATIII working, 415 V CATIII Phase to Phase
Output Pulse Amplitude
Nominal 3 V, 5 V and 14 Vpk to pk into an open circuit
Pulse width user selectable:
50m range: 7 ns, 20 ns, 40 ns,
150 ft 60 ns, 80 ns
100m range: 7 ns, 40 ns, 60 ns,
300 ft 80 ns, 100 ns
200 m ranges: 7 ns, 40 ns, 80 ns,
600 ft 140 ns, 200 ns
400 m range: 40 ns, 80 ns, 160 ns,
1200 ft 200 ns, 400 ns
1km range: 80ns, 160ns, 260 ns,
3000 ft 500 ns, 1 ms
2km range: 160 ns, 260 ns,
6000 ft 500 ns, 1 ms, 2 ms
4km range: 240 ns, 500 ns,
12000 ft 1 ms, 2 ms, 4 ms
8km range: 500 ns, 1 ms, 2 ms,
24000 ft 4 ms, 8ms
16km range: 1 ms, 2 ms, 4 ms,
48000 ft 8 ms, 16 ms
(Default pulse width for each range underlined)
Gain: 0 to 90 dB in steps of 6 dB
Velocity Factor
Variable from 0.300 to 0.999 in steps of 0.001
TX Null: 0 ½ to 120 ½
Screen Update Rate
Once per second or three times per second, (user selectable).
Power Down
Automatic after 5, 10 or 15 minutes with no keys pressed, (user selectable).
Backlight
Stays on for 1, 2 or 5 minutes when activated, (user selectable).
Communications Port
RS-232C compatible 1 start bit, 8 data bits, 1 stop bit and no parity, 19200 baud standard
Internal Memory: Storage capacity of 15 waveforms and data

size (9.8 H x 7.9 W x 4.3 D in.)
Shipping Weight 10.0000
Power Supply Eight LR6 (AA) type batteries
Manufacturer Megger
MPN 6411-012
Manufacturer Warranty 1 Year
Mitchell Catalog Number 9F655535E, 8F655535E, 7F655535E

Product Tags

Add Your Tags:
Use spaces to separate tags. Use single quotes (') for phrases.


 

My Cart

You have no items in your shopping cart.

Compare Products

You have no items to compare.

 
  Loading...
Thank You For Shopping with Mitchell Instrument Company Inc.® - 1570 Cherokee St. San Marcos CA 92078 - Call Toll Free: (888) 270 2690 - Fax (800) 648 2411