Your One Stop Stocking Distributor - Mitchell Instrument Company - call toll free: (888) 270 2690

Skip to Main Content »

Search Site
Welcome! Have Questions? Call us at: (888) 270 2690

dynasonics fusion ultrasonic flowmeter

Double click on above image to view full picture

Zoom Out
Zoom In

More Views

  • dynasonics fusion ultrasonic flowmeter

Dynasonics Fusion Hybrid Ultrasonic Flow Meter

Mitchell Part Number: DYJ-DFSN2

Availability: Typically In stock - Call if Urgent!

$1,200.00

Quick Overview

The Dynasonics Fusion Hybrid Flow Meter utilizes both Doppler and transit time ultrasonic sound techniques and automatically selects the correct technology to calculate the flow rate.  This dual technology allows the Fusion to accurately measure the volumetric flow of clean, solids-bearing or gaseous liquids on full pipes. Adverse flow conditions – surges, particulate, gas pockets, etc. – will not clog, damage or influence accuracy of the “flow-through” Fusion design.

* Required Fields

$1,200.00
Add Items to Cart Add to Cart

Be the first to review this product

Automatically switches between Doppler and transit time to determine best technology and calculate accurate flow rates
Utilizes flow-through stainless steel flow sensors
Rugged, all metal construction ensures a long service life in harsh outdoor environments
Simultaneous display of flow rate and accumulated total on a large, easy to read LCD display
Total reset through keypad, RS485 command or momentary contact of a terminal block connection to ground
Modbus command set permits flow rate, total and total reset access
All configuration parameters and flow totals are backed up indefinitely in FLASH memory
Outputs include 4-20 mA, RS485 (Modbus), rate pulse and total pulse


OPERATING PRINCIPLE


The Fusion consistently measures liquid flow by using both Doppler and transit time ultrasonic hardware and algorithms. It automatically determines which principle to use, providing the most accurate measurement for the present conditions of the application. The Fusion’s dual technology is capable of reliably measuring clean, dirty and gassy liquids - Patent Pending. When in transit time mode, the flow meter operates by transmitting and receiving a frequency modulated burst of sound energy between two transducers. The burst is first transmitted in the direction of fluid flow and then against fluid flow (see Figure 1). Since sound energy in a moving liquid is carried faster when it travels in the direction of fluid flow (downstream) than it does when it travels against fluid flow (upstream), a differential in the times of flight will occur. The difference between the two travel times is then used to calculate the flow rate. When in Doppler mode, the flow meter transmits an ultrasonic sound from its transmitting transducer into the flowing liquid. The sound will be reflected by sonic reflectors (gas bubbles or particulate) suspended within the liquid and recorded by the receiving transducer. If the sonic reflectors are moving within the sound transmission path, sound waves will be reflected at a frequency shifted (Doppler frequency) from the transmitted frequency. The shift in frequency will be directly related to the speed of the moving particle or bubble, resulting in a liquid flow rate that is interpreted by the instrument and converted to various user defined measuring units. Fusion retains all user configured data and accumulated flows (totalizers) in non-volatile Flash memory indefinitely.

Specifications

Measurement Type: Ultrasonic Doppler and transit time hybrid, automatic selection
Input Voltage: 12-30 Vdc @ 0.1 A Max; reverse polarity protection; auto-reset polyfuse; transient voltage suppression
Flow Range: ½ Inch*: 0.20 -15.0 GPM (6.9 - 514 BPD) 0.8 - 57 LPM (0.05 - 3.40 M3/H)
                   1 Inch: 0.7 - 60 GPM (24 - 2057 BPD) 2.6 - 227 LPM (0.16 - 13.6 M3/H)
                   2 Inch: 3.00- 250 GPM (102.9 - 8571 BPD) 11.4 - 946 LPM (0.70 - 56.80 M3/H)
Accuracy: 1% of Rate over the top 10:1 measuring range, single-phase liquids
Pressure Temperature: 300 PSI (2,070 kPa); -30 to +160 °F (-34 to +70 °C)
Outputs: Fusion cannot output 4-20mA and Rate Pulse simultaneously; selection via keypad entry
4-20mA: 12-bit; source from DC supply voltage; scalable to flow rate via keypad entry
Rate Pulse: 0-1,000 Hz scalable to flow rate via keypad entry; open collector; internal/external pull-up; TTL square-wave or turbine flow meter simulation; 50% duty cycle
Total Pulse: Open collector, internal/external pull-up; 33 mSec duration
RS485: 1/4-node; 128 addresses, 9.6/19.2 kb; Modbus command set
Rate Units: GPM, BPD, LPM, M3/H
Total Units: GAL, BBL, LIT, M3
Wetted Materials: 316 SS, polyetherimide, Buna-N (alternate o-ring materials can be provided)
Enclosure: NEMA 4; powder coated aluminum, SS, polycarbonate, urethane, PVC
Electrical Ports: (2) ½" NPT (1) ¾" NPT
Display Flow Rate: auto ranging 4-digit LCD
Flow Total: 8-digit, E-2 to E+3 exponents
Approvals: Class I Division 2 Groups C&D; CSA 22.2 No. 142 & 213, UL 508, ISA 12.12.01

Shipping Weight 8.0000
Power Supply 115VAC
Manufacturer Dynasonics
MPN DFSN2
Manufacturer Warranty 1 Year

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.



Thank You For Shopping with Mitchell Instrument Company Inc.® - 1570 Cherokee St. San Marcos CA 92078 - Call Toll Free: (888) 270 2690 - Fax (800) 648 2411