DVI500T Big Digital Voltage Indicator With Capacitive Test Point Mode

Double click on above image to view full picture

Zoom Out
Zoom In

More Views

  • DVI500T Big Digital Voltage Indicator With Capacitive Test Point Mode
  • DVI500T Big Digital Voltage Indicator With Capacitive Test Point Mode
  • DVI500T Big Digital Voltage Indicator With Capacitive Test Point Mode

HD Electric DVI500T Big Digital Voltage Indicator

Mitchell Part Number: HDJ-DVI500T

Availability: Typically In stock - Call if Urgent!

$1,034.00
Add Items to Cart Add to Cart

Quick Overview

HD Electric DVI500T Big Digital Voltage Indicator With Capacitive Test Point Mode


Indicates Voltage up to 500 kV with Capacitive Test Point Mode, Kit Includes DVI-500T, (1) HP-DVI-2, (1) HP-DVI-6, (1) IEP-DVI-5 and CS-DVI-5 Case


Hot Stick is required for use-See Related Products for Hot Sticks.


Hot Stick is not inlcuded.

Be the first to review this product

The New DVI500T units are designed to be used on both transmission and distribution systems in both overhead and underground applications. The DVI-500 indicates voltage from 0.1kV – 9.9kV and from 10kV - 500kV with no range selector switch or settings required. Voltage is displayed on a large 1.45” LED display with a 3-digit readout. In addition, an audible alarm alerts the user to the presence of voltage above 100VAC. The DVI units are auto shut-off and will turn off after 4 minutes of inactivity.


The DVI units have a built-in self test, activated by pressing and holding the ON button. For a test using an external voltage source, the PT-DVI Voltage Indicator Tester should be used before and after each test to verify proper operation. Two overhead probes are supplied with the DVI-500 units - a large 6” overhead hook probe for transmission system use (HP-DVI-6) and a smaller 2” overhead hook probe for distribution system use (HP-DVI-2). Simply attach the correct probe for the proper overhead application. Use of an appropriate length hotstick is required for all overhead and underground applications.


The use of an underground probe (IEP-DVI-5) is required for underground or pad mount applications as well as any applications up to 21kV line-to-ground where the DVI will be used in close proximity to grounded conductors or surfaces.


The DVI500T can be used in underground applications to measure elbow test points using the underground probe. To switch the DVI-500T to Test Point Mode, simply press the ON button again and a flashing decimal appears in the lower right corner of the display. Use of an appropriate length hotstick is required for all overhead and underground applications.


FEATURES
• For use on system voltages up to 800kV (reads up to 500kV line-to-ground)
• No range selector switch or settings required
• Large LED display indicates the line-to-ground voltage level
• Display is easy to read in bright or dark conditions
• Voltage readout allows the user to distinguish between nominal
and induced voltages
• Audible indication when voltage is detected
• Measure elbow test points with the DVI-500T
• Built-in universal spline for standard hotstick attachment
• Built-in self test to verify proper operation
• Auto shutoff with low battery function
• Powered by a field replaceable 9V alkaline battery
• Compact, rugged and lightweight polycarbonate housing
• Kits are available, contact factory for details


 

Specifications

DVI-500 SPECIFICATIONS

Model Numbers:  DVI-500T

Operating Voltage Range: 0-500kV line-to-ground (0.1kV – 9.9kV and 10kV to 500kV)

Operating Frequency: 50 – 60Hz

Operating Temperature Range: -40°F to + 120°F (-40°C to +49°C)

Dimensions:
Housing: 4.25”H x 7”W x 4.5”D
(10.8cm x 17.8cm x 11.4cm)

Overhead Probes: HP-DVI-2: 8” long (20.3cm)

HP-DVI-6: 12” long (30.4 cm)

Weight: 1.37 lb. with small overhead probe (0.62 kg)

LED Height: 1.45 inches (3.7 cm)

Accuracy: Laboratory calibrated to +/-3% Typical overhead line accuracy in compact overhead three phase configuration +/-25%

Power Supply:
Field replaceable 9-volt alkaline battery
Battery Life: About 100 readings with
9V alkaline battery

Standard Overhead Probes:
(for overhead use only) HP-DVI-2 and HP-DVI-6

Carrying Case: CS-DVI-5 Rugged Plastic Carrying Case

Optional Underground Probe: (for underground use only) IEP-DVI-5 - for 15, 25 and 35kV Class

Shipping Weight 25.0000
Manufacturer HD Electric
MPN DVI-500T

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.



Thank You For Shopping with Mitchell Instrument Company Inc.® - 1570 Cherokee St. San Marcos CA 92078 - Call Toll Free: (888) 270 2690 - Fax (800) 648 2411