Check items to add to the cart or select all
Be the first to review this product
The New DVI500T units are designed to be used on both transmission and distribution systems in both overhead and underground applications. The DVI-500 indicates voltage from 0.1kV – 9.9kV and from 10kV - 500kV with no range selector switch or settings required. Voltage is displayed on a large 1.45” LED display with a 3-digit readout. In addition, an audible alarm alerts the user to the presence of voltage above 100VAC. The DVI units are auto shut-off and will turn off after 4 minutes of inactivity.
The DVI units have a built-in self test, activated by pressing and holding the ON button. For a test using an external voltage source, the PT-DVI Voltage Indicator Tester should be used before and after each test to verify proper operation. Two overhead probes are supplied with the DVI-500 units - a large 6” overhead hook probe for transmission system use (HP-DVI-6) and a smaller 2” overhead hook probe for distribution system use (HP-DVI-2). Simply attach the correct probe for the proper overhead application. Use of an appropriate length hotstick is required for all overhead and underground applications.
The use of an underground probe (IEP-DVI-5) is required for underground or pad mount applications as well as any applications up to 21kV line-to-ground where the DVI will be used in close proximity to grounded conductors or surfaces.
The DVI500T can be used in underground applications to measure elbow test points using the underground probe. To switch the DVI-500T to Test Point Mode, simply press the ON button again and a flashing decimal appears in the lower right corner of the display. Use of an appropriate length hotstick is required for all overhead and underground applications.
FEATURES
• For use on system voltages up to 800kV (reads up to 500kV line-to-ground)
• No range selector switch or settings required
• Large LED display indicates the line-to-ground voltage level
• Display is easy to read in bright or dark conditions
• Voltage readout allows the user to distinguish between nominal
and induced voltages
• Audible indication when voltage is detected
• Measure elbow test points with the DVI-500T
• Built-in universal spline for standard hotstick attachment
• Built-in self test to verify proper operation
• Auto shutoff with low battery function
• Powered by a field replaceable 9V alkaline battery
• Compact, rugged and lightweight polycarbonate housing
• Kits are available, contact factory for details
| Specifications | DVI-500 SPECIFICATIONS Model Numbers: DVI-500T Operating Voltage Range: 0-500kV line-to-ground (0.1kV – 9.9kV and 10kV to 500kV) Operating Frequency: 50 – 60Hz Operating Temperature Range: -40°F to + 120°F (-40°C to +49°C) Dimensions: Overhead Probes: HP-DVI-2: 8” long (20.3cm) HP-DVI-6: 12” long (30.4 cm) Weight: 1.37 lb. with small overhead probe (0.62 kg) LED Height: 1.45 inches (3.7 cm) Accuracy: Laboratory calibrated to +/-3% Typical overhead line accuracy in compact overhead three phase configuration +/-25% Power Supply: Standard Overhead Probes: Carrying Case: CS-DVI-5 Rugged Plastic Carrying Case Optional Underground Probe: (for underground use only) IEP-DVI-5 - for 15, 25 and 35kV Class |
| Shipping Weight | 25.0000 |
| Manufacturer | HD Electric |
| MPN | DVI-500T |